medical software development since 1999  
  • Sante PACS Server

  • Sante PACS Server

  • Sante PACS Server

  • Sante PACS Server


Sante PACS Server


Automatic CD/DVD burning and printing of received studies

Sante PACS Server when receiving studies, except of storing on the disk it can also send them automatically for CD/DVD burning and label printing to robotic disk publisher devices of EPSON and PRIMERA.



For this purpose it uses two additional AE Titles, one with the addition of "_E" suffix in the original AE Title and one with the addition of "_P" suffix.
E.g.
If the defined AE Title is SANTESRV1, the program creates the AE Titles SANTESRV1_P and SANTESRV1_E as well. These additional AE Titles are used for automatic CD/DVD burning and printing.



  • If a client DICOM node (a CT/MR/US/DX or other medical scanner, a DICOM workstation etc.) instead of using the original AE Title of Sante PACS Server it uses the AE Title with the "_E" suffix, then Sante PACS Server stores the received series/studies on the database and automatically sends them for printing and burning to an EPSON producer.
  • If a client DICOM node (a CT/MR/US/DX or other medical scanner, a DICOM workstation etc.) instead of using the original AE Title of Sante PACS Server it uses the AE Title with the ,"_P" suffix, then Sante PACS Server stores the received series/studies on the database and automatically sends them for printing and burning to an PRIMERA producer.

Delayed automatic CD/DVD burning and printing of received studies

Some medical scanners use multiple connections to send a whole study (usually one connection per series of the study). In that case the program by using the AE title with "_E" and "_P" suffixes that described in the previous paragraph, will create one CD/DVD per connection, that is one CD/DVD for every series, and not one CD/DVD for the whole study that contains all the series of the patient.

In that case the client DICOM node (a CT/MR/US/DX or other medical scanner, a DICOM workstation etc.) must use the AE Title with a "_TE" or "_TP" suffix. With these suffixes the program waits for a specific time before sending the received series of the study for printing and burning. If it receives a new series that belong to the study in delay, it waits again the secified time for the next series and so on. If it does not receive in the specified time a series that belong to the study in delay, it sends the study for burning and printing.

The user specifies the delay time in the control Delay Time (sec) control of the dialog box below. The default value is 120 sec.